CONSTANT CURRENT DISCHARGE CHARACTERISTICS (A), (25℃)
CONSTANT WATTAGE DISCHARGE CHARACTERISTICS (WATT), (25℃)
CAPACITY FACTORS WITH DIFFERENT TEMPERATURE
MAINTENANCE & CAUTIONS
Charging Procedure:
Every month, recommend inspection every battery voltage
Every three months, recommend equalization charge for one time. Equalization charge method:
Step 1: Discharge: 100% rate capacity discharge.
Step 2: Charge: Max. Current 0.3CA, constant voltage 2.40-2.45V/Cell charge 24h.
Length of service life will be directly affected by the number of discharge cycles,depth of discharge, Ambient temperature and charging voltage.
Charge the batteries at least once every six months, if they are stored at 25℃. Charging Method:
Constant Voltage: -0.2C×2h+2.40~2.45V/cell×24h, Max. Current 0.25CA
Constant Current: -0.2C×2h+0.1C×12h
Fast: -0.2C×2h+0.3C×4h
Terminal of torque: