Add to Cart
SCUEnergyStorageSolutions2022
■ Multiple working modes.
■ Seamless switching between on-grid and off grid modes,<10ms.
■ 3P3W and 3P4W optional.
■ RS485, CAN, Ethernet communication modes.
■ Functions of low voltage ride through and reactive power compensation. ■ 100% unbalanced load capacity in off grid operation.
■ Continuous 105% rated output power.
■ AC and DC dual input redundant power supply.
■ Modular design and flexible product.
■ High efficiency,high reliability.
■ Battery technology independence.
■ PV direct access.
High efficiency integrated PCS systems based on 50kW module
Model | EPCS50 EPCS100 EPCS150 EPCS200 | EPCS250 | ||
Battery | Voltage range | DC 680V-900V (without TX) / 580V-900V (with TX) | ||
Max DC channel Qty | 1 2 3 4 | 5 | ||
interface | ||||
parameters | ||||
Single channel maximum current | 85A | |||
Output | 3W+N+PE/3W+PE | 3W+N+PE/3W+PE |
Rated power | 50kW | 100kW | 150kW | 200kW | 250kW |
Rated voltage | AC 380V /400V | ||||
Rated Current | 75A | 151A | 227A | 303A | 379A |
AC grid- Voltage range | -15% ~ +10% |
Output | 3W+N+PE/3W+PE | |||||
Rated power | 50kW | 100kW | 150kW | 200kW | 250kW | |
Rated voltage | AC 380V /400V | |||||
Rated frequency | 50Hz/60Hz | |||||
AC off-grid | Rated Current | 75A | 151A | 227A | 303A | 379A |
Voltage accuracy | 0.01 | |||||
parameters | ||||||
Frequency accuracy | ±0.2Hz | |||||
Output voltage harmonics | 3%@ linear full load | |||||
Unbalanced load capacity | 100% | |||||
Overload capacity | 105%]: continuous operation; (105% ~ 120%]: 10min; (120% ~ 125%]: 1min; 125%); stop | |||||
operation |
Others | Communication | CAN/RS485 | ||
Isolation | Isolation Tranformer Optional | |||
Protection | IP20 | |||
Cooling | Air cooling, intelligent fan regulation | |||
Maximum efficiency | 98.5%(no transformer) | |||
Dimension W*D*H | 600*1000*2000 | 1200*1000*2000 | ||
Weight | 300kg 330kg 500kg 530kg | 560kg | ||
Certification | EN50549/G99/IEC62477-1/EN61000/IEC61727/IEC62116 |
Model | EPCS300 | EPCS400 EPCS500 | EPCS600 | |
Battery | Voltage range | DC 680V-900V (without TX) / 580V-900V (with TX) | ||
Max DC channel Qty | 3 | 4 5 | 6 | |
interface | ||||
parameters | ||||
Single channel maximum current | 170A |
|
Output | 3W+N+PE/3W+PE | ||
Rated power | 300kW | 400kW 500kW | 600kW |
Rated voltage | AC 380V /400V | ||
Rated Current | 454A | 606A 758A | 909A |
AC grid- Voltage range | -15% ~ +10% |
AC off-grid parameters | Output | 3W+N+PE/3W+PE |
Rated power | 300kW 400kW 500kW 600kW | |
Rated voltage | AC 380V/400V/415V | |
Rated frequency | 50Hz/60Hz | |
Rated Current | 454A 606A 758A 909A | |
Voltage accuracy | 1% | |
Frequency accuracy | ±0.2Hz | |
Output voltage harmonics | 3%@ linear full load | |
Unbalanced load capacity | 100% | |
Overload capacity | 105%]: continuous operation; (105% ~ 110%]: 10min; 110%); stop operation |
Others | Communication | CAN/RS485 | ||
Isolation | Isolation Tranformer Optional | |||
Protection | IP20 | |||
Cooling | Air cooling, intelligent fan regulation | |||
Maximum efficiency | 98.5%(no transformer) | |||
Dimension W*D*H | 1400*1000*2000 | 1400*1000*2000 | ||
Weight | 600kg 650kg 700kg | 750kg | ||
Certification | EN50549/G99/IEC62477-1/EN61000/IEC61727/IEC62116 |